ZenTrades

Fire Sprinkler System

Fire Sprinkler System Antifreeze Solution Concentration Test Checklist

Fire Sprinkler System Antifreeze Solution Concentration Test Checklist

Ensure your fire sprinkler system stays effective with our Antifreeze Solution Concentration Test template. Simplify your maintenance routine by effortlessly monitoring antifreeze levels. This comprehensive tool helps you maintain optimal concentration, ensuring your system performs reliably in emergencies. Download now for seamless testing and peace of mind.

Is the antifreeze solution concentration test being performed in accordance with NFPA 13? *
Are the proper testing tools and equipment available for conducting the test? *
Is the antifreeze solution temperature within the acceptable range for testing? *
Is the antifreeze solution sample being collected from the correct location in the system? *
Is the sample being collected in a clean and uncontaminated container? *
Is the sample being properly labeled with the system information and test date? *
Is the refractometer or other testing device calibrated and functioning properly? *
Was the refractometer or testing device properly cleaned before use? *
Is the antifreeze solution sample being mixed thoroughly before testing? *
Is the refractometer or testing device being held level during testing? *
Is the test result being recorded accurately on the testing log? *
Is the test result being compared to the acceptable concentration range specified by the manufacturer? *
Is the test result within the acceptable concentration range for the antifreeze solution? *
Is the antifreeze solution being properly labeled with the test result? *
Is the test log being signed and dated by the individual performing the test? *
Is the test log being reviewed and approved by the designated authority? *
Is the system being properly flushed and refilled if the antifreeze concentration is outside the acceptable range? *
Is the system being properly tagged and documented after the test is completed? *
Are all necessary notifications being made to the appropriate authorities if the antifreeze concentration is found to be out of range? *
Is the system being properly monitored and retested at the specified intervals? *
Are all personnel involved in testing the antifreeze solution properly trained and qualified? *
Are all safety precautions being followed during the testing process? *
Is the testing area properly ventilated to prevent exposure to fumes? *
Are all waste materials being disposed of properly after testing? *
Are all documentation and records being kept in accordance with NFPA and AHJ requirements? *
Fire Sprinkler System Antifreeze Solution Concentration Test Checklist