nfpa

NFPA 13R, Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies

NFPA 13R concentrates on sprinkler designs for low-rise residential properties, aiming to control fires and enhance protection in multi-family housing complexes.
Current Version: 2020
Revision Cycle: Custom ERRS Group 5 Fall 2025
Next Edition: 2026
Status: Active

NFPA 13R Summary

The NFPA 13R, Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies 2020, serves as a comprehensive guide for designing and installing automatic sprinkler systems to safeguard residential buildings against fire hazards. This standard is tailored for buildings up to four stories high and not exceeding 60 ft (18 m) in height above the grade plane. Built upon the premise that the sprinkler system should effectively combat fires originating from a single ignition source, NFPA 13R does not encompass requirements for water mist fire protection systems, which are distinct and addressed separately by NFPA 750. The primary objective of NFPA 13R is to furnish a sprinkler system that aids in fire control within residential settings, enhancing protection against injury and loss of life in multi-family dwellings. It was conceived to bridge the gap between NFPA 13 and NFPA 13D, thereby promoting greater adoption of sprinkler systems in multi-family buildings. Central to NFPA 13R is its focus on providing life safety to occupants while also optimizing system affordability through tailored material selection, design specifications, and judicious sprinkler placements.

What is the key differences between NFPA 13R, 2020 and its preceding version?

Let's delve into the differences between the current version of NFPA 13R (Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies) and its previous version. 1. Scope and Purpose: - Current NFPA 13R: Developed to bridge the gap between NFPA 13 and NFPA 13D, NFPA 13R encourages more sprinkler system installations in multi-family buildings. - Previous NFPA 13R: The earlier version also aimed at life safety in low-rise residential occupancies but had less stringent requirements compared to the current version. 2. Risk Considerations: - Current NFPA 13R: Recognizes the increased risk in multifamily occupancies due to factors like higher occupant loads, stacked dwelling units, and longer egress times. - Previous NFPA 13R: Had a more generalized approach without specific considerations for multifamily buildings. 3. System Goals: - Current NFPA 13R: Focuses on providing life safety to occupants while also reducing system costs through material choices, design requirements, and selective sprinkler placement. - Previous NFPA 13R: Shared similar goals but with less emphasis on cost-effectiveness. 4. Installation Limitations: - Current NFPA 13R: Applicable to residential occupancies up to four stories in height, not exceeding 60 ft (18 m) above grade plane. - Previous NFPA 13R: Had similar limitations but may not have been as specific. 5. Property Protection: - Current NFPA 13R: Provides a higher level of property protection than NFPA 13D but less than NFPA 13. - Previous NFPA 13R: Offered a degree of incipient property protection but not as reliable as NFPA 13. In summary, while both versions of NFPA 13R prioritize life safety, the current version enhances property protection and addresses the unique challenges of multifamily buildings. Swapping between NFPA 13 and NFPA 13R is not a straightforward exchange due to their distinct goals.
To gain access to complimentary handbooks and a 14-day trial for NFPA’s premium resources, it is necessary to register an account on their portal.

Book a free demo

Digitalize your Inspections with ZenFire

  • Faster Inspection
  • Deficiency Reporting
  • Proposals

Transforming fire inspection workflows,
boosting revenue 4x in 6 months!

How Inland Fire increased their monthly revenues by 4 times in less than 6 months using ZenFire

ZenFire | Inland Fire Safety
Aaron Simonsen
Owner, Inland Fire

Book Now